Trouble and Solution of Heating in Hydraulic System of Concrete Pump

Concrete pump hydraulic system heating fault and troubleshooting:

First, the concrete pump hydraulic system heating phenomenon hazards

Concrete pump hydraulic system heating, a direct impact on the normal operation of concrete pumps, fever caused by the hazards, mainly in the following points: (1) the working fluid temperature increases, the viscosity of the working fluid decreased pump leakage increased, The actual flow of the pump has decreased; (2) the hydraulic system and components of the seals metamorphism at high temperatures, elastic degeneration ability to reduce the sealing performance, or seal failure, so that leakage increases; (3) When the thermal expansion coefficient is different, the valve core is stuck due to thermal expansion between the valve core and the valve body, so that the concrete pump can not work. (4) When the viscosity of the working fluid drops, the lubrication of the working fluid Decreased performance, hydraulic components accelerated wear and tear accelerated wear and tear components, shortening the service life of components. Machinery and equipment maintenance network In order to avoid the occurrence of these phenomena, some concrete pumps have to stop after a certain period of time, so that the system cooling, thereby reducing the concrete pump boot rate, affecting the construction schedule. Therefore, we should take into account the causes of system heat, take appropriate measures to control the temperature of the hydraulic system to ensure the normal use of concrete pumps.

Second, the concrete pump hydraulic system heating the main reasons and troubleshooting

The heating of the hydraulic system can be divided into two categories according to the causes of the heat: one is the heat caused by the design; the other is the heat caused by the failure or improper use of the hydraulic components. Obviously, different causes of fever, the exclusion method is not the same.

1, the design is not reasonable:

(1) improper use of hydraulic oil number may cause heating of the hydraulic system The selected hydraulic oil at low oil temperatures, the system works normally, but the system is working for some time, the oil temperature increases, the viscosity of hydraulic oil decreased, resulting in Increased internal system leakage, with the increase in leakage also led to an increase in oil temperature, the formation of a vicious circle of oil temperature. The solution is: According to the system load and normal operating temperature requirements, select the appropriate viscosity of the hydraulic oil.

(2) Unreasonable fuel tank design: reduce the heat dissipation effect of the hydraulic system. The main function of the system heating oil tank is to store the hydraulic oil, but it also has the functions of dissipating heat, precipitating impurities and separating water. Fuel tank design is unreasonable, mainly in two aspects: First, the fuel tank volume design is too small, because the concrete pump is a mobile hydraulic equipment, the fuel tank volume is generally double the hydraulic pump flow, so the tank cooling area and oil reserves Second, some of the tanks in the structural design is not reasonable, the suction nozzle and the return pipe port closer, no separator in the middle, thus shortening the oil in the tank cooling cycle and the path of precipitation of impurities, or even Resulting in most of the return oil directly into the suction pipe, reducing the cooling effect of the fuel tank, increasing the oil temperature. The solution is to increase the tank volume appropriately to make the tank volume (1125 ~ 115) Q, and try hard to increase the distance between the suction pipe mouth and the oil return pipe mouth. The partition plate should be set between the suction pipe and the oil return pipe to ensure that the fuel tank Should have cooling power.

(3) smaller heat flux: cooler installation location is unreasonable, the cooling capacity of the system to reduce the cooling concrete pump with air-cooled and water-cooled two, the user can choose according to the actual situation, but the general use of air-cooled more. Some concrete pumps consider the pressure requirements of the cooler, the cooler is set on the oil return line of the stirring system, and only the oil of the stirring system is cooled. Due to the small flow rate of the stirring system, the cooling effect of the entire system is poor, fever. Solution: First, an independent cooling circuit can be used to improve the cooling effect. The second is to set the cooler in the system total oil return to increase the heat flow, improve cooling effect, but this time should pay attention to two problems, the first issue is the cooling fan speed, cooling fan speed can not be too low, Otherwise it will reduce the cooling effect, you can use the motor to drive the fan, or in the total oil return road set a low-voltage drive motor, the motor speed and cooling flow to match, but also can solve the main circuit pressure impact on the cooler pressure capacity; The second problem is the use of motor-driven fan, the main system of the pressure impact on the cooler pressure capacity, this time, the return line with the cooler and install a low pressure overflow protection valve or check valve for cooling The highest pressure protection device.

(4) improper selection of hydraulic components: resulting in system heating Concrete pump hydraulic system is generally high-pressure high-flow system, if the system of hydraulic components, mainly reversing valve, relief valve and sequence valve size selection is not reasonable, can not meet the large Flow requirements, which in use, so that the flow velocity of the valve port flow is too high, resulting in greater pressure loss and the oil temperature, therefore, hydraulic system design in the selection of hydraulic components design, must be based on hydraulic components The maximum working pressure to be sustained, the maximum flow rate passed, and the required range of pressure and flow adjustment to minimize the pressure loss at the valve port and to reduce the heating of the system due to the unreasonable selection of hydraulic components.

(5) pipeline design, installation unreasonable: resulting in large pressure loss, so that the pressure can be converted into heat energy in the hydraulic system design, piping design and installation can not be ignored, the pipeline diameter should be strictly in accordance with the pressure of work and through Flow design, to avoid too small diameter design, resulting in high flow velocity, along the pressure loss is too large, causing fever. At the same time, it should also pay attention to the installation of the pipeline, it is necessary to achieve the appearance of tidy, but also to avoid pipelines gather and pipe sharp turn, affect the natural cooling pipe or cause local pressure loss caused by excessive heat.

2, due to improper use of hydraulic system or component failure, resulting in heat and its elimination of hydraulic system

(1) The hydraulic oil level in the fuel tank is lower than the minimum liquid level: the fuel tank cooling power is reduced Concrete pump in use, we should always observe the level of hydraulic oil in the tank, always maintain the hydraulic oil level in the normal oil level Range, so as to ensure the cooling effect of the tank. When the hydraulic oil level in the tank is lower than the minimum level, it is necessary to oil the tank in time.

(2) The cooling effect of the cooler is lowered and the temperature of the oil is raised: The cooling effect of the system cooling decreases. This may be caused by the following reasons: a1 Cooler internal blockage or excessive surface dirt causes the cooler safety device to open. The cooler Therefore, the concrete pump must be regularly checked in use, to clear the cooler, periodically on the cooler surface Dirt removal, to ensure smooth internal cooler and external cleaning, to ensure cooler cooling effect. b1 cooler relief valve or check valve opening pressure is lower than the standard value, so that the cooler safety protection device is open when the cooler is not blocked, resulting in overflow shunt, cooler cooling flow to reduce, therefore, the cooler before use , We must correctly adjust the opening pressure of the safety protection device, in the use of regular inspection to correct the safety protection device opening pressure value.

(3) improper adjustment of hydraulic system pressure: heat system In concrete pump hydraulic system, due to performance requirements, the system often have safety valves, relief valves and sequence valves. If the safety valve pressure is too low, the safety valve will be frequently opened, resulting in overflow loss, resulting in system fever; if the pressure is too high, it will increase the system leakage, the system fever, therefore, should be hydraulic system Load requirements, correct calculation and adjustment of safety valves and pressure values ​​to ensure that the system operates within the specified pressure range. When the main pump of the pump system is a closed system, the heat exchange circuit must be installed in the pumping system. The set pressure of the relief valve in the heat exchange circuit should be taken seriously. If the set pressure is too low, the pump hydraulic pressure Cylinder commutation increases, set the pressure is too high, will make the overflow loss is too large, the system temperature is too high. Therefore, should be reasonable to determine the heat exchanger circuit relief valve pressure adjustment value, the general adjustment value of the relief valve (1 ~ 115) MPa, pumping system working pressure of the oil circuit is 215MPa. When setting the sequence valve in the hydraulic system of the concrete pump, we must understand the working characteristics of the sequence valve and correctly adjust the working pressure of the sequence valve. If the internal control sequence valve to adjust the pressure is too high, when the working pressure of the hydraulic cylinder is lower than the adjustment pressure, there is pressure loss of the sequence valve port, causing temperature rise, resulting in system fever, a reasonable set of internal control sequence valve settings Pressure, the working pressure of the working cylinder is higher than the opening pressure of the sequence valve. When the sequence valve is in operation, the valve port will be fully open and the valve port will be substantially pressure-free, thereby avoiding the system heat caused by the improper setting of the sequence valve .

(4) The internal leakage increases, the oil temperature can be increased: the system heat concrete pump hydraulic system of internal leakage, including hydraulic pump, hydraulic cylinder, hydraulic motor and hydraulic valve internal leakage, pressure oil in the leakage process, the pressure drop, Temperature rises. If the system increases the internal leakage, will cause the oil temperature to rise, the system overheated, serious, it will make the system pressure drop, poor pumping, pumping displacement decreased, stirring weak, mixing speed decline. Therefore, regular inspection of these components, the replacement of the corresponding sealing components on a regular basis, the timely replacement of damaged or injured parts replacement or repair, or even replace the corresponding hydraulic components, so as to avoid component leakage caused by the system heat.

Concrete pump hydraulic system fever in the course of the problem has become one of the problems can not be ignored, due to the heating of the hydraulic system will lead to many concrete pump failure occurred. For concrete pump manufacturers, should strive to start from the design, the heating system of its hydraulic system to a minimum, this will not only increase the user's concrete pump boot rate and extend its life, but also save energy and reduce maintenance costs; for concrete pump Users should strive to start from the use and maintenance, in strict accordance with the requirements of manufacturers, the proper use, commissioning, inspection, maintenance of concrete pumps to reduce the failure rate and reduce the system due to improper use of fever. In short, for different causes of fever, take some measures, you can control or reduce the heat of the hydraulic system to increase the boot rate of concrete pumps and extend the service life.

More Search Keywords: Pumps

Wire Cage Welding and Forming Machine

The Spun pile cage forming welding machine is a fully automatic professional equipment for producing reinforced steel cage of concrete spun piles. The welding strength of the whole equipment is small, the forming is fast, the structure is reasonable, the maintenance is simple. Combined with modern frequency conversion control and man-machine interface, it is effective to ensure the stable and reliable quality of the steel cage.

PC wire cage welding machine

The technical parameters:

No.

Item

Specification

1

cage welding dia.

ø300 .ø400. ø500. ø600

2

length of cage welding

7M-15M(special cases is extended to 45M)

3

The number of longitudinal reinforcement bar

6.7.10 or 7.10.12.14 etc.(according to user's requirement)

4

Longitudinal reinforcement bar diameter

ø7.1.ø9.0.ø10.7

5

Ring reinforcement diameter

ø4- ø6

 

6

The cage body pitch

0-100mm

 

7

Pulling speed

MAX7500mm/min

8

Driving Power

8.4KW

 

9

Welding power

300KVA

10

Rotational speed of main engine

0-64r/min

11

Welding manner

ERW(electric resistance welding)

 

12

Control manner

Automatic control

 

No.

Item

Technical specification

13

Welding material

Any steel with a carbon content of less than 0.20%

14

Loss of solder strength

≤5%

15

Tension or shear at the solder joints

≥200KG

16

Welding transformer cooling mode

wind cooling,self-cooling

17

welder power supply

380V±5%  50HZ

18

environment temprature

-5℃--+35℃

19

 Relative humidity

<85%

20

welder weight

≈5T


Cage Welding and Forming Machine

Steel Wire Straightening Machine,Cage Welding And Forming Machine,Steel Bar Cage Forming Machine,Cage Mesh Welding Forming Machine

Jiangsu Haiheng Building-Materials Machinery Co.,Ltd , https://www.jshaiheng.com