The HAE TIJ printer offers an idea solution to move from messy low resolution Drop On Demand (DOD), Roller Coders or expensive to operate and service continuous inkjet marking printer (CIJ) to a high quality, high resolution HAE Thermal Ink Jet Printer (TIJ) using the latest original HP ink cartridges for reliable print onto primary and secondary packaging. A compact, low cost solution for Lot Codes, Date and Time, Sell by and Best Before and Use-By Dates, Product Information, Batch and Production data, Traceability Codes, Specifications, Branding, Sequential numbers, Expiry dates, bar codes, logo and free text to meet your coding needs. Simple to use and PC software included with the HAE Inkjet marker makes complex messages easy to manage and to easily back up or move to other HAE TIJ coding printers for security of code.
Tij Inkjet Printer,TIJ Inkjet Coder,Thermal Inkjet Printer,Date Coding Machine,Inkjet Marking Machine,Inkjet Marking Printer,Thermal Inkjet Printer Wuhan HAE Technology Co., Ltd. , https://www.whuvwallprinter.com
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Genset Model
Â
HDGM450/6
HDGM500/6
HDGM550/6
HDGM688/6
HDGM825/6
HDGM1000/6
HDGM1375/6
HDGM1876/6
HDGM2500/6
Engine Model
Â
PTA780BG2
PTAA780BG2
PTAA890BG2
PTAA1120BG2
PTAA1340BG2
QTA2160BSG2
QTA3240BSG2
QTA4320BSG2
QTA5400BSG2
Rating SpeedÂ
rpm
1800
1800
1800
1800
1800
1200
1200
1200
1200
FrequencyÂ
Hz
60
60
60
60
60
60
60
60
60
Generator Continuous Output (COP)
kW
260Â
280Â
360Â
400Â
540Â
640Â
900Â
1200Â
1560Â
Generator Prime Output (PRP)
kW
320Â
360Â
400Â
500Â
600Â
720Â
1000Â
1365Â
1800Â
Generator Standby Output (LTP)
kW
360Â
400Â
440Â
550Â
660Â
800Â
1100Â
1500Â
2000Â
Power Factor
Â
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Gas Engine Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Engine Continuous Output  (COP)
kW
297Â
316Â
407Â
456Â
616Â
722
964Â
1244Â
1617Â
Engine Prime Output  (PRP)
kW
361Â
402Â
445Â
562Â
680Â
804
1098Â
1485Â
1865Â
Engine Standby Output  (LTP)
kW
404Â
445Â
503Â
615Â
744Â
880
1203Â
1624Â
2073Â
Configuration
Â
6 In line
6 In line
8Â Vee
10Â Vee
12Â Vee
8Â Vee
12Â Vee
16Â Vee
20Â Vee
DisplacementÂ
l
12.8
12.8
14.6
18.3
21.9
35.4
53.1
70.8
88.5
BoreÂ
mm
128
128
128
128
128
170
170
170
170
StrokeÂ
mm
166
166
142
142
142
195
195
195
195
Compression Ratio
Â
15.5:1
15.5:1
14.6:1
14.6:1
14.6:1
13.5:1
13.5:1
13.5:1
13.5:1
Piston SpeedÂ
m/s
9.96
9.96
8.52
8.52
8.52
7.8
7.8
7.8
7.8
Number of Flywheel TeethÂ
Â
160Â
160Â
160Â
160Â
160Â
218Â
218Â
218Â
218Â
Flywheel House Size
Â
SAE1-14
SAE1-14
SAE1-14
SAE1-14
SAE1-14
SAE00-18
SAE00-21
SAE00-21
SAE00-21
System Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Oil CapacityÂ
l
40
40
32
40
45
160
180
240
300
Max. Allowed Oil TemperatureÂ
°C
110
110
110
110
110
110
110
110
110
Oil Pressure WarningÂ
kPa
200Â
200Â
200Â
200Â
200Â
300Â
300Â
300Â
300Â
Oil Pressure ShutdownÂ
kPa
160Â
160Â
160Â
160Â
160Â
200Â
200Â
200Â
200Â
Coolant Capacity for EngineÂ
l
18
18
20
21
23
70
100
140
200
Max. Coolant Warning Temperature Â
°C
95
95
95
95
95
93
93
93
93
Max. Coolant Shutdown Temperature Â
°C
105
105
105
105
105
97
97
97
97
Flow of Coolant pumpÂ
m³/h
23.6
23.6
30.5
30.5
36
38/36
38/36
64/60
64/60
Max. Exhaust Temperature
°C
525
520
480
500
500
500
480
500
530
Exhaust Flow
m³/min
44
48
60
67
81
196
297
428
504
Exhaust Flange DiameterÂ
mm
125
125
2*100
2*100
2*125
250
2*250
2*250
2*250
Charging Alternator CapacityÂ
A
35
35
35
35
35
55
55
55
55
Starting VoltageÂ
V
24
24
24
24
24
24
24
24
24
Fuel & Gas Consumption (PRP)
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Fuel Consumption at 75% Load
l/h
21
23
29Â
34Â
40Â
48Â
55Â
80Â
94Â
Gas Consumption at 75% Load
m³/h
36
41
72
81
98
120
149
215
253
Fuel Consumption at 100% Load
l/h
28
31
39
44
53
62
74
107
126
Gas Consumption at 100% Load
m³/h
49
54
96
108
130
159
198
286
337
Generator Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Generator Model
Â
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-1L/4
ECO40-2L/4
MX-750-6
MX-1000-6
MX-1500-6
MX-1800-6
Generator Prime Output
kW
336
384
432
528
653
750
1000
1500
1800
Generator Efficiency @ 0.8PF
Â
94.3%
95.0%
94.7%
95.2%
95.8%
95.3%
95.4%
95.5%
96.3%
Genset Dimension
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
LengthÂ
mm
3100
3100
3300
3500
3600
4600
5200
5600
*Â 5600
WidthÂ
mm
1300
1300
1500
1500
1500
2190
2190
2190
*Â 1800
HeightÂ
mm
1700
1700
2000
2000
2000
2300
2580
2800
*Â 2400
Genset Weight
kg
2500
2500
3500
3900
4300
7650
10500
13500
16500
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kW
Note:
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Series Dual Fuel Generator, 1800rpm/1200rpm, 60Hz
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Genset Model
Â
HDGM450/6
HDGM500/6
HDGM550/6
HDGM688/6
HDGM825/6
HDGM1000/6
HDGM1375/6
HDGM1876/6
HDGM2500/6
Engine Model
Â
PTA780BG2
PTAA780BG2
PTAA890BG2
PTAA1120BG2
PTAA1340BG2
QTA2160BSG2
QTA3240BSG2
QTA4320BSG2
QTA5400BSG2
Rating SpeedÂ
rpm
1800
1800
1800
1800
1800
1200
1200
1200
1200
FrequencyÂ
Hz
60
60
60
60
60
60
60
60
60
Generator Continuous Output (COP)
kW
260Â
280Â
360Â
400Â
540Â
640Â
900Â
1200Â
1560Â
Generator Prime Output (PRP)
kW
320Â
360Â
400Â
500Â
600Â
720Â
1000Â
1365Â
1800Â
Generator Standby Output (LTP)
kW
360Â
400Â
440Â
550Â
660Â
800Â
1100Â
1500Â
2000Â
Power Factor
Â
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Gas Engine Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Engine Continuous Output  (COP)
kW
297Â
316Â
407Â
456Â
616Â
722
964Â
1244Â
1617Â
Engine Prime Output  (PRP)
kW
361Â
402Â
445Â
562Â
680Â
804
1098Â
1485Â
1865Â
Engine Standby Output  (LTP)
kW
404Â
445Â
503Â
615Â
744Â
880
1203Â
1624Â
2073Â
Configuration
Â
6 In line
6 In line
8Â Vee
10Â Vee
12Â Vee
8Â Vee
12Â Vee
16Â Vee
20Â Vee
DisplacementÂ
l
12.8
12.8
14.6
18.3
21.9
35.4
53.1
70.8
88.5
BoreÂ
mm
128
128
128
128
128
170
170
170
170
StrokeÂ
mm
166
166
142
142
142
195
195
195
195
Compression Ratio
Â
15.5:1
15.5:1
14.6:1
14.6:1
14.6:1
13.5:1
13.5:1
13.5:1
13.5:1
Piston SpeedÂ
m/s
9.96
9.96
8.52
8.52
8.52
7.8
7.8
7.8
7.8
Number of Flywheel TeethÂ
Â
160Â
160Â
160Â
160Â
160Â
218Â
218Â
218Â
218Â
Flywheel House Size
Â
SAE1-14
SAE1-14
SAE1-14
SAE1-14
SAE1-14
SAE00-18
SAE00-21
SAE00-21
SAE00-21
System Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Oil CapacityÂ
l
40
40
32
40
45
160
180
240
300
Max. Allowed Oil TemperatureÂ
°C
110
110
110
110
110
110
110
110
110
Oil Pressure WarningÂ
kPa
200Â
200Â
200Â
200Â
200Â
300Â
300Â
300Â
300Â
Oil Pressure ShutdownÂ
kPa
160Â
160Â
160Â
160Â
160Â
200Â
200Â
200Â
200Â
Coolant Capacity for EngineÂ
l
18
18
20
21
23
70
100
140
200
Max. Coolant Warning Temperature Â
°C
95
95
95
95
95
93
93
93
93
Max. Coolant Shutdown Temperature Â
°C
105
105
105
105
105
97
97
97
97
Flow of Coolant pumpÂ
m³/h
23.6
23.6
30.5
30.5
36
38/36
38/36
64/60
64/60
Max. Exhaust Temperature
°C
525
520
480
500
500
500
480
500
530
Exhaust Flow
m³/min
44
48
60
67
81
196
297
428
504
Exhaust Flange DiameterÂ
mm
125
125
2*100
2*100
2*125
250
2*250
2*250
2*250
Charging Alternator CapacityÂ
A
35
35
35
35
35
55
55
55
55
Starting VoltageÂ
V
24
24
24
24
24
24
24
24
24
Fuel & Gas Consumption (PRP)
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Fuel Consumption at 75% Load
l/h
21
23
29Â
34Â
40Â
48Â
55Â
80Â
94Â
Gas Consumption at 75% Load
m³/h
36
41
72
81
98
120
149
215
253
Fuel Consumption at 100% Load
l/h
28
31
39
44
53
62
74
107
126
Gas Consumption at 100% Load
m³/h
49
54
96
108
130
159
198
286
337
Generator Parameter
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Generator Model
Â
ECO38-3LN/4
ECO40-1S/4
ECO40-2S/4
ECO40-1L/4
ECO40-2L/4
MX-750-6
MX-1000-6
MX-1500-6
MX-1800-6
Generator Prime Output
kW
336
384
432
528
653
750
1000
1500
1800
Generator Efficiency @ 0.8PF
Â
94.3%
95.0%
94.7%
95.2%
95.8%
95.3%
95.4%
95.5%
96.3%
Genset Dimension
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
LengthÂ
mm
3100
3100
3300
3500
3600
4600
5200
5600
*Â 5600
WidthÂ
mm
1300
1300
1500
1500
1500
2190
2190
2190
*Â 1800
HeightÂ
mm
1700
1700
2000
2000
2000
2300
2580
2800
*Â 2400
Genset Weight
kg
2500
2500
3500
3900
4300
7650
10500
13500
16500
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 320kw-1800kw
Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
Model NO.: PTA, QTA Series
Mixture: 30% Diesel ,70% Natural Gas
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: Guangdong, China
HS Code: 8502120000
60Hz Googol Natural Gas Diesel Fuel Dual Engine for Generator 260kW-1560kW