Feiyiya Inclined Plate Clarifiers Use Gravity & Innovative Engineering
A gravity clarifier is the most economical method of removing solids from liquids, using natural gravity as the source of energy and it is free. A clarifier simply provides a non-turbulent zone where heavier than liquid solids, suspended by turbulence, are given sufficient time to settle to a quiescent surface. The HEI inclined plate clarifiers are compact units with multiple layers of settling area utilizing less than 25% of the floor space required by conventional clarifiers.
Principle of Clarifiers
A particle carried forward by the velocity of the liquid flow must settle at a rate that allows it to reach the bottom before passing through the clarifer. Thus, particles beginning at a point [a" must traverse some route lying between ab and ab` in order to avoid being carried over the outlet.
If V is the horizontal velocity of the liquid, S the solids particle vertical settling velocity, L the length of the settling device, and D its depth, then particles entering at point A will settle to the bottom of the device only if V does not exceed: S(L/D)Since Vmax / S = L / D then, Vmax = S (L / D)
Inclined plate clarifier, Lanmei inclined plate clarifier, Inclined Tube Settler,High-Efficiency Inclined Tube Wuxi Feiyiya Environmental Protection Technology Co., Ltd. , https://www.feiyya.com
Outstanding Ergonomic Design
Top Optical & Mechanical Design
Excellent Technology And Quality
SZ 680 series Specifications(0.68X~4.7X.)
Â
Type
SZ 680
Magnification Range
0.68X~4.7X.
Zoom Ratio
1 : 6.8
Actual Field of Image Space
Φ23mm
Working Distance    Â
110 mm
Stereo Angle        Â
12°
Viewing Angle       Â
35°
Interpupillary Distance Adjustment Â
50 mm to 75 mm
Auxiliary Objective
0.5X
0.75X
1X(Built-in)
1.5X
2X
Working Distance
189mm
122mm
110mm
42mm
36mm
Eyepieces 10X /φ23mm
Magnification
3.4 to 23.5
5.1 to 35.25
6.8 to 47
10.2 to 70.5
13.6 to 94
Actual Field(mm)
67.6 to 9.79
45.1 to 6.52
33.82 to 4.89
22.55 to 3.26
16.91 to 2.45
Eyepieces 15X /φ16mm
Magnification
5.1 to 35.25
7.65 to 52.88
10.2 to 70.5
15.3 to 105.8
20.4 to 141
Actual Field(mm)
47.06 to 6.81
31.37 to 4.53
23.53 to 3.40
15.69 to 2.27
11.76 to 1.70
Eyepieces 20X /φ12mm
Magnification
6.8 to 47
10.2 to 70.5
13.6 to 94
20.4 to 141
27.2 to 188
Actual Field(mm)
35.29 to 5.11
23.53 to 3.40
17.65 to 2.55
11.76 to 1.70
8.82 to 1.28
SZ650/680/810 Series Zoom Stereo Microscope Outfit
Items
SZ650BP
SZ650B2L
SZ680BP
SZ680B2L
SZ810BP
SZ810B2L
Main Body
Binocular
--
--
--
--
--
--
Trinocular
Â
Â
â—‹
â—‹
â—‹
â—‹
10XEyepiece/Φ22mm
--
--
Â
Â
Â
Â
10XEyepiece/Φ23mm
Â
Â
--
--
Â
Â
10XEyepiece/Φ24mm
Â
Â
Â
Â
--
--
15XEyepiece/Φ16 mm
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
20XEyepiece/Φ12mm
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
â—‹â—‹
0.5X/2X Objective
â—‹
â—‹
â—‹
â—‹
â—‹
â—‹
Focusing unit
--
--
--
--
--
--
No light
--
Â
--
Â
--
Â
Reflecting 3W LED
Â
--
Â
--
Â
--
Transmitting 3W LED
Â
--
Â
--
Â
--
Black & white Plate
--
--
--
--
--
--
Glass Plate
Â
--
Â
--
Â
--
Arm stand
--
--
--
--
--
--
Pillar stand
â—‹
â—‹
â—‹
â—‹
â—‹
â—‹
Focusing Arm stand
â—‹
â—‹
â—‹
â—‹
â—‹
â—‹
Base (330×300mm)
--
--
--
--
--
--
C-mount  0.5X,0.7X,1X
Â
Â
â—‹
â—‹
â—‹
â—‹
 Â
Â
Therefore, the velocity at which a horizontal clarifying device may be operated successfully is directly proportional to its length and inversely proportional to its depth.
This analysis applies to multiple horizontal plate units also. The spacing between plates is usually a few inches as opposed to a depth of several feet in a horizontal tank; therefore, [settling-out" times are dramatically reduced. The flow must be non-turbulent to prevent settled solids from being re-entrained within the moving liquid. Small plate spacing and a large surface area permits laminar flow at higher velocities than large horizontal tanks would allow.
Horizontal clarifying devices become self-flushing if they are inclined at an angle which exceeds the angle of repose of the settled solids. In such cases, flow enters the lower end of the device where settling particles move to the floor eventually sliding back out the entrance. Clear effluent leaves the top of the device.
However, when the device is inclined, the furthest settling particles no longer fall through distance D but some longer distance D`. This new longer settling distance D` is related to D by the relation: D = D` cos Ø.
Theta [Ø" is the angle, the device is inclined to the horizontal plane. Thus settling distance is increased by the factor: 1/cos Ø In the case where Ø = 60º, 1/cos Ø = 2.
The maximum settling distance is twice the distance between the plates. It is apparent then that the lower the angle of inclination, the smaller the settling distance. However, the angle of inclination must exceed the angle of repose of the solids to be separated. The previous equation may be modified to express the cosine of an inclined plate clarifying system as:
Vmax = L / (D / cosØ) (s) = L·cosØ / D (s)
Inclined Plate Clarifiers
A reduction of the required floor space is acquired by diminishing the separation between the horizontal plates to a few inches and stacking the settling surfaces. Inclining the plates to provide self flushing, 45º for heavy particles and 60º for light particles, reduces the available horizontal projected area (effective settling area) by a factor equivalent to the cosine of the angle. The surface area diagram (below) graphically compares the floor space requirements of an HEI inclined plate clarifier with the equivalent horizontal projected settling area.
Settling Rate
The settling rate for a specific solids should be determined by standard laboratory tests. Light particles, such as metal hydroxides, usually require a design parameter of 0.25 – 0.50 gallons per minute per square foot of horizontal projected area. These low density solids require the inclined plates to be set at a 60º angle to induce the particles to slide down the plate. Heavier particles (such as sand that easily flow) will readily slide from plates set at a 45º angle.
Maximum flow rate of an inclined plate clarifier is based on the flow rate per unit of a horizontally projected surface area. Retention time in the clarifier is not a design criteria. However, attaining optimum performance requires the prudent design to recognize several additional, very important factors.
Dental Microscope for Resolution Stereo Microscope LED
Model NO.: SZ680
Shape: Cylindrical Shaped Lens
Usage: Teaching, Research, Industry
Principle: Optics
Principle of Optics: Differential Interference Contrast Microscope
Magnification Range: 3.4X-188X
Zoom Ratio: 1:6.8
Actual Field of Image Space: 23mm
Working Distance: 110mm
Stereo Angle: 12°
Viewing Angle: 40°
Interpupillary Distance Adjustment: 50-75mm
Eyepiece: Wf10X20mm
Objective: 0.5X/2X
Light Source: 3W
Trademark: Optec
Transport Package: Cartons
Specification: 480X370X470(mm)
Origin: Chongqing
HS Code: 9011100000
SZ 680 series Zoom-stereo Microscope
SZ 680 series zoom stereo microscope is an all-new with Galilean Optical System. The quality is up to international level. Magnification range reaches 0.68X~4.7X.