Plastic Panel Film,Transparent Pe Film,High Viscosity Protective Film,Scratch Protection Pe Film Wuxi Xinhao Protective Film CO.,Ltd , https://www.zjprotectivefilm.comTEST-905 PORTABLE 5000A PRIMARY CURRENT INJECTION TEST SYSTEM FOR CIRCUIT BREAKER TESTING
TEST-905 primary current injection test system adopts ARM chip to control the output process and large capacity of toroidal transformer. It is equipped with LCD screen display current meter, also showed primary current value, secondary current value, turn ratio and the phase shift. Aluminum alloy body with PC panel component the shell.
TEST-905 is mainly applied to test CT turn ratio and polarity in the power system, the contact resistance, high voltage circuit breaker protection test and high voltage generator test etc, which need large current on-site or in the lab.FEATURES
PARAMETERS
Electrical parameters
Accuracy
±0.5%
Power Supply(AC)
380V·70A, 50Hz/60Hz
Current Output (AC)
5000A·5V or 2500A·10V
Capacity
25KVA
The current output waveform distortion
≤5%
Primary current
Range
0-5500A
Resolution
0.1A
Accuracy
<0.5%
Secondary measurement
Range
0-6A
Resolution
0.001A
Accuracy
<0.5%
Current duration
5000A range
5000AÂ Â Â Â 2-3minutes
2500AÂ Â Â Â Â 3-6minutes
2500A range
2500AÂ Â Â Â Â 2-3minutes
With timer
Range
0.0001~999.99S
Resolution
0.001S
Accuracy
<0.5%±5 words
Mechanical parameters
Dimensions (W×D×H) (mm)
430×430×445 and 550×450×600
Weight(kg)
Control Host 68kg,
External voltage regulator weight 55kgEnvironmental conditions
Temperature
-10°C to 40°C
Relative humidity
≤80%
SELECTION GUIDE
 Model
ACCU
RACYPrimary
currentAMMETER
(0-6A)TIMER
POWER
INJECTION CURRENT TIME
DIMENSION(W×D×H)(mm)
WEIGHT
REMARK
TEST-901
0.5%
0-1100A
YES
YES
5KVA
1000A: 2-3min;
500A:3-6min430×260×260
25KG
Integrated structure
TEST-902
0.5%
0-2200A
YES
OPTIONAL
12KVA
2000A:2-3min;
1000A:3-6min360×300×295 and 320×300×300
35KG+15KG
Fission structure
TEST-903
0.5%
0-3300A
YES
OPTIONAL
15KVA
3000A:2-3min;
1500A:3-6min380×350×360 and 340×290×420
48KG+42KG
Fission structure
TEST-905
0.5%
0-5500A
YES
OPTIONAL
25KVA
5000A:2-3min;
2500A:3-6min430×430×445 and 550×450×600
68KG+55KG
Fission structure
Â
TEST-905 PORTABLE 5000A PRIMARY CURRENT INJECTION TEST SYSTEM FOR CIRCUIT BREAKER TESTING
TEST-905 primary current injection test system adopts ARM chip to control the output process and large capacity of toroidal transformer. It is equipped with LCD screen display current meter, also showed primary current value, secondary current value, turn ratio and the phase shift. Aluminum alloy body with PC panel component the shell.
TEST-905 is mainly applied to test CT turn ratio and polarity in the power system, the contact resistance, high voltage circuit breaker protection test and high voltage generator test etc, which need large current on-site or in the lab.FEATURES
PARAMETERS
Electrical parameters
Accuracy
±0.5%
Power Supply(AC)
380V·70A, 50Hz/60Hz
Current Output (AC)
5000A·5V or 2500A·10V
Capacity
25KVA
The current output waveform distortion
≤5%
Primary current
Range
0-5500A
Resolution
0.1A
Accuracy
<0.5%
Secondary measurement
Range
0-6A
Resolution
0.001A
Accuracy
<0.5%
Current duration
5000A range
5000AÂ Â Â Â 2-3minutes
2500AÂ Â Â Â Â 3-6minutes
2500A range
2500AÂ Â Â Â Â 2-3minutes
With timer
Range
0.0001~999.99S
Resolution
0.001S
Accuracy
<0.5%±5 words
Mechanical parameters
Dimensions (W×D×H) (mm)
430×430×445 and 550×450×600
Weight(kg)
Control Host 68kg,
External voltage regulator weight 55kgEnvironmental conditions
Temperature
-10°C to 40°C
Relative humidity
≤80%
SELECTION GUIDE
 Model
ACCU
RACYPrimary
currentAMMETER
(0-6A)TIMER
POWER
INJECTION CURRENT TIME
DIMENSION(W×D×H)(mm)
WEIGHT
REMARK
TEST-901
0.5%
0-1100A
YES
YES
5KVA
1000A: 2-3min;
500A:3-6min430×260×260
25KG
Integrated structure
TEST-902
0.5%
0-2200A
YES
OPTIONAL
12KVA
2000A:2-3min;
1000A:3-6min360×300×295 and 320×300×300
35KG+15KG
Fission structure
TEST-903
0.5%
0-3300A
YES
OPTIONAL
15KVA
3000A:2-3min;
1500A:3-6min380×350×360 and 340×290×420
48KG+42KG
Fission structure
TEST-905
0.5%
0-5500A
YES
OPTIONAL
25KVA
5000A:2-3min;
2500A:3-6min430×430×445 and 550×450×600
68KG+55KG
Fission structure
Â
Portable 5000A Primary Current Injection Test System for Circuit Breaker Testing
Model NO.: TEST-905
Weight: 100-500Kg
Power Source: AC380V
Trademark: GFUVE
Transport Package: Standard Export Wooden Box
Specification: TEST-905 0-5500A 25kva
Origin: Beijing China
Model NO.: TEST-905
Weight: 100-500Kg
Power Source: AC380V
Trademark: GFUVE
Transport Package: Standard Export Wooden Box
Specification: TEST-905 0-5500A 25kva
Origin: Beijing China
Â
Â