ANSI Blind Flange,150Lbs Blind,Class600 Blind,600Lbs Bl Flanges Hebei Welkin Pipe Fitting Manufacturing Co., Ltd , https://www.welkinpipeline.com
They chose YINUO
General
LSZ-Jacket flowmeter find extensive use in flow measuring appliations where process materials tends to become highly visous, solidify, or extract as line temperature drops, or where process fluids must be controlled at a specific temperature. Measurement is made while steam or hot oil is allowed to circulate through the jacked enclosure.
Â
 Features
Â
Construction and Liquid to be metered( Fullly Jacketed)
Â
 Sectional View
 Description
Liquids to be metered
Â
Â
Pocketless construction( transmission system: Magnetic coupling)
Max. operating pressure( pressure of fluid to be metered):1.18MPa
Bitumen, DMT, phthalic
Anhydride,
Naphthalene, etc.
Â
Â
Â
Construction and Liquid to be metered( Standard Jacketed)
 General Specification
              Item
            Description
Nominal size mm
08~400
Construction
Double-case construction
Applicable fluid
Water petroleum liquid foods chemical liquids
Flow range
See flow range table
Operating temp.range
+
+80~+150°C
+150°C~+250°C
Accuracy
0.2%
0.5%
Repeatability
0.067%
0.167%
Materials
Body
Cast steel or 304 stainless steel or 316 stainless steel
Rotors
Cast steel or 304 stainless steel or 316 stainless steel
Bearings
Cast steel or 304 stainless steel or 316 stainless steel
Â
Register Specifications Model M1
Item
Description
Meter size
Round Mechanical Register
Units Indicated
Stere
Pointer Rotation
Clockwise
Local display(LCD)
Cumulative totalizing counter
0.1m3(std) Â 0.01m3 Â 0.001m3
Resettable counter
   No
Instantaneous flowrate
0.01m3/h(std)
Power supply
Without output signal
Installed lithium battery
With output signal
External power source 24 VDC
Ambient temperature
-40°C ~ +70°C
Explosionproof configuration
Non-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosure
IP65
Â
Â
Model VR
Item
Description
Meter size
Square Mechanical Register
Units Indicated
Stere
Local display(LCD)
Cumulative totalizing counter
0.1m3(std) Â 0.01m3 Â 0.001m3
Resettable counter
0.1m3(std) Â 0.01m3 Â 0.001m3
Instantaneous flowrate
 No
Power supply
Without output signal
Installed lithium battery
With output signal
External power source 24 VDC
Ambient temperature
-40°C ~ +70°C
Explosionproof configuration
Non-explosionproof type
Exd II CT2~T6
Degree of Protection for enclosure
IP65
Main Technical Parameters                                 Table:1
Nominal Dia. (mm)
8~400
Accuracy
±0.1%, ±0.2% and ±0.5%
Pressure loss
0~1000mPa.s<80Kpa  1000~20000mPa.2<150KPa
Nominal pressure
1.6, 2.5, 4.0, 6.4 MPa
Temperature range
-20°C ~ +80°C  +80°C ~ +150°C  +150°C ~ +250°C
Media viscosity
0~20000mPa.s
Ambient temperature
-40°C ~ +70°C
Connected flange
Can be custom-made
Photoelectric pulse(current)converter
Exd II CT6(Excluding acetylene)
Electronic meterhead
Exd II CT2-T6
For Accuracy: 0.5% and 0.2% Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Table.2
Â
Nominal
Dia.
(mm)
Flow range m3/h
Pulse equivalent liter/pulse
0.32-0.8mPa.s
0.8-2mPa.s
2-5mPa.s
5-400mPa.s
400-2000mPa.s
2000-20000mPa.s
Gasoline/ liquefied gas
Kerosene
Light diesel
Crude oil, heavy oil
Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
15
0.6-3
Â
0.4-4
Â
0.4-4
Â
0.4-4
Â
0.3-2.4
Â
0.3-2.4
Â
0.001
25
3-8
Â
1.5-10
Â
1-10
Â
1-10
Â
1-8
Â
1-6
Â
Â
0.01
Â
40
8-20
8-20
2.7-22
5.5-22
2.5-25
4.4-22
2.5-25
4.4-22
2.1-18
4.2-18
1.5-12
3-12
50
9-36
15-36
4.5-36
9-36
4-40
7.2-36
4-40
7.2-36
2.8-24
6-24
2.2-18
4.5-18
80
20-80
32-80
10-80
20-80
9-90
16-80
9-90
16-80
6.5-56
14-56
5-40
10-40
Â
Â
Â
0.1
100
25-100
40-100
13-100
25-100
12-120
20-100
12-120
20-100
8.5-72
18-72
6.5-54
14-54
150
55-225
88-220
31-250
57-225
25-250
44-220
25-250
44-220
18-150
38-150
12-100
25-100
200
90-360
150-360
50-400
90-360
40-400
72-360
40-400
72-360
28-240
53-210
20-160
40-160
250
135-540
180-540
68-540
135-540
60-600
108-540
60-600
108-540
42-360
90-360
30-240
60-240
300
220-900
300-900
112-900
225-900
100-1000
180-900
100-1000
180-900
70-600
150-600
54-450
113-450
400
400-1600
550-1600
200-1600
400-1600
180-1800
320-1600
180-800
320-1600
130-1100
275-1100
90-750
180-750
Accuracy: 0.1% Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Table.3
Â
Nominal
Dia.
(mm)
Flow range m3/h
Pulse equivalent liter/pulse
0.32-2 mPa.s
 2-5 mPa.s
5-50mPa.s   500-400          mPa.s
400-2000 mPa.s
2000-20000 mPa.s
Gasoline/ liquefied gas
Kerosene
Light diesel
Crude oil,
heavy oil
Hi-viscosity
Liquid
Liquid with high water content & super-high viscosity liquid
40
11-22
9-22
7.5-22
7.5-22
ANSI Blind Flange
Mechanical Pd Flowmeter Without Power for Oil
Model NO.: LSZ
Measuring Media: Liquid
Measuring Principle: Volumetric
Measurement Object: Closed Pipeline
Certification: JIS, DIN, GB, CE, ISO
Warranty Peroid: 12 Months After The Installation
Power Supply: 3.6V 24VDC
Signal Output: Pulse 4-20mA Hart
Working Temperature: -20 to 250 C Deg
Working Pressure: 0~64 Bar
Approval: BV CCS Ce Atex Nepsi
Material: Cast Steel Ss304 Ss316
Trademark: YINUO
Transport Package: Wooden Case
Specification: Size from 3/8inch to 16 inch
Origin: Shanghai, China.
HS Code: 9026100000
Mechanical PD flowmeter without Power for oil LSZ- Double rotator flowmeter series Thermal JacketÂ
Â