Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.
First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.
Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.
Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.
To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.
Closed Cooling Tower,Closed Circuit Cross Flow,Closed Loop Cooling Tower,Closed Circuit Cooler Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.arkfluid.com
Wood Chipper Shredder
Introduction:
It is an ideal equipment of processing the raw materials including wood branch, round logs, square blocks, and wood pieces into 10-30mm wood chips with settled dimensions.
The upper inlet and down output could be customized according to clients' requirement.
It can be driven by electric motor or diesel engine;
The series of wood chipper have solved the problem of the large difficult wood feeding.
Wood Chipper Machine is widely used in the production of paper making, edible fungus, shaving board, sawdust, high density board, and fiberboard etc.
Advantage:
1. CE approved, quality guarantee
2. High capacity and low investment
3. Structure reasonable and Firm durable
4. Safe reliable and Easy operation
Specification:
Model
knife disc Dia (mm)
knife Qty
(pcs)
Input opener
(mm)
Input Dia
(mm)
Chips size (mm)
Power
(kw)
Capacity
(t/h)
BX-600
600
3
150*140
130
20-35
22
1-3
BX-800
800
4
170*160
150
20-35
37
3-6
BX-950
950
6
220*210
200
25-35
55
8-12
BX-1200
1200
6
350*250
250
25-40
90
12-18
BX-1400
1400
6
460*350
300
25-40
110
20-30
BX-1600
1600
6
540*380
350
30-45
160
30-40
Photos of Wood Chipper:
Wood Chipping Plant:
Final Wood chips: