1800 Kw Industrial Heat Pump Type Air Cooled Screw Chiller

  • Model NO.: HWWL
  • Cooling Method: Air-cooled
  • Selected Voltage: 220V, 380V, 160V, 440V etc.
  • Noise Level: Ultra Low
  • Application Machine: Combination machine
  • Name: 1800 Kw Industrial Air Cooled Screw Water Chiller
  • Heating Capacity: 175-1312kw
  • Heating Power Input: 47.9-340kw
  • Refrigerant: R22/R407cr410A etc
  • Air Side Exchanger: Corrugated Aluminum Fin with Female Copper Tube
  • Trademark: Headpower
  • Specification: 1unit/case
  • HS Code: 8418692090
  • Type: Air-Cooled
  • Unit Structure: Integral
  • Compressor Number: It Depend on The Cooling Capacity
  • Application Fields: Air Conditioning
  • Certification: ISO, CE
  • Cooling Capacity: 138-1116kw
  • Cooling Power Input: 44.7-320kw
  • Compressor Type: 6+7 Semi-Hermetic Twin Screw
  • Heat Water Temperture: 45-50 Degree C
  • Weight: 1050-8600kgs
  • Transport Package: Plastc+Foam+Woden Case
  • Origin: Guangdong Foshan
1)The Feature of 1800 kw industrial heat pump type air cooled screw chiller
a..Excellent performance
The main body is equipped with globally advanced semi-hermetic screw compressor,intergrating the motor,without worrying about shaft seal leakage.
The single or number of compressors are provided with startup-shutdown cycle control program so as to uniformly load parts and extend their service life.
Multiple refrigrating cicuits are provided for the sigle or number of comprssors ,and when on cicuits is under maintenance,other cirucits are albe to run nomally as mutual standby.
Unload deprssurized start is provided for the compressors to prevent the impact on the power grid

b.Complete safety protections
Pressure protection:High and low-pressure protecting devices
Motor protection:Voltage-loss protection, phase-loss protection,inverse phase protection and over-heat protection.
Anti-freezing protiction:The unit will stop running in case of excessively low cooling water temperature
Safety valve protection:when the refrigerant pressure exceeds a certain value, the safety valve will be turned on automatically
Above device  protections ensure the safe and reliable running of the unit
c.Easy assembly 
The unit enjoys compact structure,covers small area,saves machine room space;it almost not vibrates due to the provision of foundation anti-vibrating measure.
Upon delivery of the units R22 refrigerant and lubricationg oil have been filed into it, then it's only necessary to connect the evaporator water pipe during assembliy,saving time and cost.

2)Product model:
Model Number HWALR150 HWALR200 HWALR250 HWALR330 HWALR400 HWALR500 HWALR600 HWALR500D HWALR650 HWALR800D HWALR1000D HWALR1200D
Cooling Capacity KW 150 182 245 322 388 498 596 490 645 776 996 1192
Heating Capacity KW 185 212 285 380 445 566 683 570 760 890 1112 1366
Cooling Power Input KW 48.2 57.7 76 99 118 148 183 252 198 236 296 366
Heating Power Input KW 47 56 74 97 113 144 178 248 194 226 288 356
Power Supply 380V/3N~50Hz
Energy Control 0~25~50~75~100% / Infinitely Variable Control
Compressor Type 6+7 Semi-closed Double Screw Type
Number 1 1 1 1 1 1 1 2 2 2 2 2
Refrigerant Type R22 (other refrigerant systems(R407C,etc) are available too.)
Way of Throttling External Balance of Thermal Expansion Valve/ Electronic Expansion Valve
Refrigerant Volume  kg 48 62 74 85 115 145 162 162 171 230 290 324
Heat Exchanger of Air Side Internal Thread Copper Tube with Aluminium Fin
Condensing Fan Type   Ultra-low Noise Axial Fan
Power KW 1.1*4 1.5*4 1.5*6 1.5*8 1.5*10 1.5*12 1.5*14 1.5*12 1.5*16 1.5*20 1.5*24 1.5*28
Heat Exchanger of Water Side Type   Dry Shell and Tube 
Cooling Water Flow m³/h 26 32 43 56 67 86 102.5 85 111 135 172 223
Heating Water Flow m³/h 28 37 49 66 77 98 118 99 131 155 192 235
Connection Pipe   DN80 DN80 DN100 DN100 DN100 DN125 DN125 DN125 DN150 DN150 DN150 DN200
Water Resistance KPa 50~60
Partial Heat Recovery Heating Capacity KW 55 65 86 114 135 170 205 170 230 268 335 410
Hot Water Volume m³/h 15.7 18.6 24.6 32.6 38.7 49 59 49 66 77 96 118
Total Heat Recovery Heating Capacity KW 158 180 245 325 380 480 580 485 646 756 945 1160
Hot Water Volume m³/h 45 52 90 93 109 138 166 139 185 217 270 320
Noise Level dB/A 64 64 65 65 66 66 67 68 68 69 70 71
Dimensions Length mm 2300 2500 3400 4400 5400 6400 7400 6400 8400 10500 6400*2 7400*2
Width mm 2200 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
Height mm 2200 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
Notice: 1. Nominal cooling condition:  inlet/outlet water temperature is 12/7ºC, the air dry/wet bulb temperature is 35/24ºC; 
2. Nominal heating condition:  inlet/outlet water temperature is 40/45ºC, the air dry/wet bulb temperature is 7/6ºC.
3. The water supply of heat recovery refers to the water volume when the water temperature increases from 20ºC to 50ºC. 
4.other refrigerant systems(R407C,etc) are available too.                               
5. The above dimensions are just for reference, they maybe modified due to improvement.
3) Dispaly:


4)Packing and shipping



5)Our company file

 

SOGAMEF

Air cooled chiller

Gabon

4

SeaService shipping

Marine air conditioner

Russia

5

EURO STANDARD LIMITED

Fresh Air Handling Unit

New Zealand

6

Henrich trading center

Air cooled/water cooled air conditioner

Philippines

7

Marine Engineering Systems Pte.Ltd

AHU, chiller,etc

Singapore

8

Elektro Werner Heitzinger

Heat recovery air handling unit

Austria

9

Nyborg Marine Equipments AS

Marine Air Handling Units

Norway

10

Wilfred Limited

Heat recovery air handling unit

UK
 