How to deal with mounting and lubrication
of gear motors
Installation and
usage of Gear reducer is directly related to its operating results, so it must
follow the technical specifications and standards. As a power transmission
structure, the normal operation of gear reducer is inseparable with the
lubricating oil, so during using, we should also pay attention to the gear
reducer's lubrication. The following are considerations about gear reducer
installation and lubrication:
1. Mounting
1) Gear reducer is generally to be
installed in the horizontal level, amount of inclination should be no more than 10°. If need amount of inclination more than 10° in special cases, , please
contact the manufacture to discuss matters before using.
2)When connect the input and output
shaft with the power and working machine, if use couplings, shafts should be
aligned strictly, there shall be no decentration.When using the
V-belt and chain ,it should not be too tight or too loose.
3) The
installation foundation should be strong and reliable without vibration and
loosening. The screws should be strictly in accordance with the relevant
standards.
4) Inspect
tightness of the screws, try to use a spring washer.
2.Lubracation
1) Generally
uses oil pool lubrication for gear reducer. Add good extreme pressure gear oil
N220 or N320 to a predetermined position (20-30mm upper the low gear portion)
before using, and add regularly.
2) For first
using 50 hours, should immediately replace with new oil, and clean the
3) Replace the
oil seal leak as soon as possible when there is oil leakage.
JiangYinJiaYou
reducer Co., Ltd. is a professional high-tech company, which is engaged in
precision transmission products R & D, production and sales of high quality
gear motors. JiaYou is based on strong economic strength and superb technical
support, as well as modern management
concept and
constantly strives for innovation and excellence business purpose to provide
high quality products, excellent after-sales service to create maximum value
for customers.
oil inside the
body. After that completely replace once every three months.